HIGH-STRENGTH THREADLOCKER NT272
For general-purpose applications. Once cured, the anaerobic compound is resistant to high temperatures, constant and variable mechanical loads, and exposure to industrial media, including oils, greases, fuels, gases, water, seawater, and steam.The polymerized (cured) anaerobic compound does not deteriorate with age.
Product available in two packaging options: bottle and pump dispenser.
Product Benefits:
Prevents loosening of components exposed to vibration, such as mounting bolts in pumps, gearboxes, and presses
Suitable for all metals, including passive substrates such as stainless steel, aluminum, and plated surfaces
Tolerates slight contamination with industrial oils, including engine oils, anti-corrosion oils, and coolants
Difficult to disassemble using standard hand tools; localized heating above 250°C may be required to loosen and disassemble the heated components
Specifications:
Bottle
Breakaway torque: 20–37 Nm
Temperature range: -50°C to +230°C
Maximum gap filling: 0.012" / 0.30 mm
Shear strength: Not applicable
Viscosity: 15,000–30,000 cPs
Fixture time / Full curing time: Less than 15 min / 24 hours
Pump Dispenser
Breakaway torque: 20–35 Nm
Temperature range: -55°C to +230°C
Maximum gap filling: 0.30 mm
Shear strength: 15–20 N/mm²
Viscosity: 8,000–15,000 mPa·s
Fixture time / Full curing time: 20–40 min / 12 hours
Applications:
- Suitable for all metal threaded connections.
Directions for Use:
During storage, the product may separate into layers. This does not affect its quality. Shake the container vigorously before use to ensure the ingredients are thoroughly mixed.
ASSEMBLY
For best bonding results, thoroughly clean all surfaces with a suitable cleaning agent.To prevent clogging of the dispensing nozzle, avoid contact between the nozzle and metal surfaces during application.Through Holes: Apply a few drops of the product to the first threads of the bolt.Blind Holes: Apply a few drops of the product to the bottom of the hole.
Sealing: Apply the product around the external threads, leaving the first thread uncovered. Ensure that the product thoroughly coats the threads.For larger threads and gaps, use an appropriate additional amount of product and also apply it around the internal threads.Assemble the joint and tighten as required.
DISASSEMBLY
Unscrew the joint using standard hand tools.If the joint is too difficult to loosen, heat the nut or bolt to approximately 250°C and disassemble while hot.